Use the Back button in your browser to see the other results of your search or to select another record.
Sensory level electrical muscle stimulation: effect on markers of muscle injury [with consumer summary] |
McLoughlin TJ, Snyder AR, Brolinson PG, Pizza FX |
British Journal of Sports Medicine 2004 Dec;38(6):725-729 |
clinical trial |
5/10 [Eligibility criteria: No; Random allocation: Yes; Concealed allocation: No; Baseline comparability: Yes; Blind subjects: No; Blind therapists: No; Blind assessors: No; Adequate follow-up: Yes; Intention-to-treat analysis: No; Between-group comparisons: Yes; Point estimates and variability: Yes. Note: Eligibility criteria item does not contribute to total score] *This score has been confirmed* |
BACKGROUND: Monophasic high voltage stimulation (MHVS) is widely prescribed for the treatment of inflammation associated with muscle injury. However, limited scientific evidence exists to support its purported benefits in humans. OBJECTIVE: To examine the efficacy of early initiation of MHVS treatment after muscle injury. METHODS: In a randomised, cross over design, 14 men performed repetitive eccentric contractions of the elbow flexor muscles followed by either MHVS or control treatment. MHVS treatments were applied five minutes and 3, 6, 24, 48, 72, 96, and 120 hours after eccentric contractions. RESULTS: MHVS resulted in a significant reduction (p < 0.05) in delayed onset muscle soreness 24 hours after eccentric exercise compared with controls. Elbow extension was significantly increased immediately after administration of MHVS compared with controls. No significant differences were observed between MHVS treatment and controls for maximal isometric strength, flexed arm angle, or arm volume. CONCLUSIONS: Early and frequent application of MHVS may provide transient relief from delayed onset muscle soreness and short term improvements in range of motion after injurious exercise. However, MHVS treatment may not enhance recovery after muscle injury because of lack of improvements in strength and active range of motion.
|