Use the Back button in your browser to see the other results of your search or to select another record.
Nasal continuous positive airway pressure facilitates extubation of very low birth weight neonates |
Higgins RD, Richter SE, Davis JM |
Pediatrics 1991 Nov;88(5):999-1003 |
clinical trial |
6/10 [Eligibility criteria: No; Random allocation: Yes; Concealed allocation: Yes; Baseline comparability: Yes; Blind subjects: No; Blind therapists: No; Blind assessors: No; Adequate follow-up: Yes; Intention-to-treat analysis: No; Between-group comparisons: Yes; Point estimates and variability: Yes. Note: Eligibility criteria item does not contribute to total score] *This score has been confirmed* |
A prospective randomized trial was performed in 58 neonates comparing nasal continuous positive airway pressure (NCPAP) versus oxyhood following extubation of neonates weighing less than 1 kg. All neonates had been ventilated for the treatment of respiratory distress syndrome for at least 24 hours and weighed less than 1 kg at the time of extubation. Clinical criteria for elective extubation included improving pulmonary status, fraction of inspired oxygen (FIO2) less than or equal to 0.35, mean airway pressure less than or equal to 7 cmH2O, ventilator rate less than or equal to 20 breaths per minute, and weight at least 80% of birth weight. Informed consent was obtained and neonates were randomized to NCPAP or oxyhood following extubation. Success was defined as remaining free of additional ventilatory support for at least 5 days. Failure criteria included FIO2 >= 0.60 to maintain pulse oximetry >= 93%, PaCO2 >= 60 mmHg, pH <= 7.23, or moderate to severe apnea. Results demonstrate that 22 (76%) of 29 neonates were successfully extubated to NCPAP while only 6 (21%) of 29 were successfully extubated to oxyhood (p < 0.0001). There were no differences in baseline characteristics between the two groups. Of the 23 neonates who failed oxyhood, 21 were then given a trial of NCPAP and 58% (12/21) remained extubated. Data indicate that using selected clinical criteria for elective extubation of neonates weighing less than 1 kg, NCPAP facilitates successful extubation.
|