Hyperinflation using pressure support ventilation improves secretion clearance and respiratory mechanics in ventilated patients with pulmonary infection: a randomised crossover trial |
Lemes DA, Zin WA, Guimaraes FS |
Australian Journal of Physiotherapy 2009;55(4):249-254 |
clinical trial |
7/10 [Eligibility criteria: Yes; Random allocation: Yes; Concealed allocation: Yes; Baseline comparability: Yes; Blind subjects: No; Blind therapists: No; Blind assessors: No; Adequate follow-up: Yes; Intention-to-treat analysis: Yes; Between-group comparisons: Yes; Point estimates and variability: Yes. Note: Eligibility criteria item does not contribute to total score] *This score has been confirmed* |
QUESTION: Is ventilator-induced hyperinflation in sidelying more effective than sidelying alone in removing secretions and improving respiratory mechanics in ventilated patients with pulmonary infection? DESIGN: Randomised crossover trial with concealed allocation and intention-to-treat analysis. PARTICIPANTS: 30 mechanically ventilated patients with pulmonary infection in an adult intensive care unit. INTERVENTION: The experimental intervention was 30 minutes of ventilator-induced hyperinflation using pressure support ventilation in sidelying; the control intervention was 30 minutes of sidelying. Participants received both interventions on the same day, with a five-hour washout period between them. OUTCOME MEASURES: Secretion clearance was measured as sputum volume retrieved during the intervention. Respiratory mechanics were measured as static compliance and total resistance of the respiratory system before and after the intervention. RESULTS: The experimental intervention cleared 1.3 ml (95% CI 0.5 to 2.2) more secretions than the control. After ventilator-induced hyperinflation in sidelying, respiratory compliance had increased 4.7 ml/cmH2O (95% CI 2.6 to 6.8) more than in sidelying alone. There was no difference in total resistance of the respiratory system between the interventions (mean difference 0.3 cmH2O/l/s, 95% CI -0.8 to 1.3). CONCLUSION: The application of hyperinflation using pressure support ventilation in mechanically ventilated patients with pulmonary infection improves secretion clearance and increases static compliance of the respiratory system.
|