Use the Back button in your browser to see the other results of your search or to select another record.
| Comparison between automatic tube compensation and continuous positive airway pressure during spontaneous breathing trials |
| Figueroa-Casas JB, Montoya R, Arzabala A, Connery SM |
| Respiratory Care 2010 May;55(5):549-554 |
| clinical trial |
| 5/10 [Eligibility criteria: Yes; Random allocation: Yes; Concealed allocation: No; Baseline comparability: No; Blind subjects: Yes; Blind therapists: No; Blind assessors: No; Adequate follow-up: Yes; Intention-to-treat analysis: No; Between-group comparisons: Yes; Point estimates and variability: Yes. Note: Eligibility criteria item does not contribute to total score] *This score has been confirmed* |
|
Copyright release for this abstract has not been granted.
|