Acceleration of tibia and distal radius fracture healing in patients who smoke
Cook SD, Ryaby JP, McCabe J, Frey JJ, Heckman JD, Kristiansen TK
Clinical Orthopaedics and Related Research 1997 Apr;(337):198-207
clinical trial
8/10 [Eligibility criteria: No; Random allocation: Yes; Concealed allocation: Yes; Baseline comparability: Yes; Blind subjects: Yes; Blind therapists: No; Blind assessors: Yes; Adequate follow-up: Yes; Intention-to-treat analysis: No; Between-group comparisons: Yes; Point estimates and variability: Yes. Note: Eligibility criteria item does not contribute to total score] *This score has been confirmed*

A low intensity ultrasound device was investigated as an accelerator of cortical and cancellous bone fracture healing in smokers and nonsmokers. Statistically significant reductions in healing time for smokers and nonsmokers were observed for tibial and distal radius fractures treated with an active ultrasound device compared with a placebo control device. The healing time for a tibial fracture was reduced 41% in smokers and 26% in nonsmokers with the active ultrasound device. Similarly, distal radius fracture healing time was reduced by 51% in smokers and 34% in nonsmokers with the active device. Treatment with the active ultrasound device also substantially reduced the incidence of tibial delayed unions in smokers and nonsmokers. The use of the active ultrasound device accelerates cortical and cancellous bone fracture healing, substantially mitigates the delayed healing effects of smoking, speeds the return to normal activity, and reduces the long-term complication of delayed union.
For more information on this journal, please visit http://www.lww.com.

Full text (sometimes free) may be available at these link(s):      help